From account creation to first reading: self-service setup, what to have ready, and why most customers finish setup in under two hours. Use the questions below to understand the decision points, evidence, and follow-up work for your operation.
Published Last updated
What happens before activation?
Setup is self-service: create your TankActive account, add your locations, and connect your automatic tank gauge (ATG) using the guided setup. For supported Omntec Proteus ATGs, choose Add by Serial Number and follow the on-device VPN and serial-number steps. Have your gauge details, equipment access, and any required network permissions ready. If you hit a problem, support is available by email or phone.
Supported Omntec Proteus deployments can often connect without replacement hardware. That is not a blanket promise for every Proteus configuration: model, software, interface, network access, and current condition still need to be confirmed. Veeder-Root, Franklin Fueling, and other ATG systems are reviewed during setup, and compatibility and the connection method are confirmed before activation rather than assumed.
Before you start, list the locations, tanks, products, users, and supported data you expect to monitor. Identify the operating contact who can validate the gauge and the IT or network contact who can authorize connectivity. A clear scope avoids treating a working data path as complete when tank mappings or access assignments are still unresolved.
What information should you have ready?
Provide source information rather than guesses. Photos of the gauge label and communication interfaces can help identify the model and installed options, but they should not expose passwords or other credentials. If the software version or network owner is unknown, mark it for discovery so the installation plan does not depend on an unverified detail.
Use the product’s Location terminology consistently. The location name, address, tank numbers, and products should match the organization’s operating records closely enough that users can recognize them. Decide who has authority to correct a mismatch before data is activated.
- Location name, address, and primary contact.
- ATG manufacturer, model, software version, and a clear equipment photo.
- Tank and product details that can be checked against the gauge.
- The network or IT contact if the connection uses location infrastructure.
- Known VPN, firewall, cellular, power, access, or maintenance constraints.
- The people who need dashboard or mobile access and the organization role each person should receive.
How is the connection method confirmed?
Connectivity may use an existing VPN, a cellular connection, or a direct ATG network connection, depending on the location and gauge. The choice should be approved by the people who own the network and equipment. It should limit access to the required purpose, document dependencies, and name the team responsible for future support.
An existing VPN may fit a centrally managed fleet. Cellular may separate the ATG path from the business network but requires suitable coverage, power, equipment access, and service ownership. A direct network connection may use existing gauge capability only when the specific deployment and access design are supported. Do not expose an ATG to the public internet or make an unapproved firewall change to speed up activation.
Share sensitive connection details through the approved secure channel. Record the final path in a location-level handoff without placing credentials in screenshots, public documents, or general support notes.
What are the setup steps?
- 1Create your TankActive account and open Add a location from Admin or Manage locations. Have your ATG identity, configuration details, and required access ready.
- 2Choose Add by Serial Number for a supported Proteus ATG. Follow the on-device VPN steps, enter a Location Name, and enter the 9-character serial number twice before selecting Add Location.
- 3If you use another supported connection method, follow its guided setup and test the connection. Ask your network or equipment owner about required access; contact TankActive support by email or phone if you need help.
- 4Confirm that the connected ATG is the intended data source and check the location, tank, and product mappings.
- 5Check received inventory, supported ATG status, alarms, and other available data against the gauge with someone who knows the location.
- 6Invite authorized users, review their access assignments, and confirm who owns operational notifications.
- 7Keep a record of your connection details, checks, and any open questions. Contact support@tankactive.com or +1 (631) 981-2001 if you need help completing setup.
How long does installation take?
Most customers finish setup in under two hours per location once required access and information are ready. Setup time varies with the ATG, connection path, equipment access, and location details; it is a typical customer experience rather than a guaranteed completion time.
A new network path, unconfirmed interface, onsite service need, weak cellular coverage, firewall approval, unavailable IT owner, equipment issue, or missing location data can extend the schedule. Check these dependencies before starting setup where possible, and contact support by email or phone if you need help.
Measure completion by validated scope rather than elapsed time. A connection that reaches a gauge but has unverified tank mappings, missing user access, or unresolved data questions is still an open implementation. Document those items and assign owners rather than declaring completion to preserve a target duration.
How are readings and mappings validated?
First confirm that your connection reaches the intended ATG. Then compare the location, tank numbers, products, current inventory, and ATG status with the source gauge and known location conditions. This two-part check catches both transport errors and meaning errors.
Tank inventory and status update every 15 minutes by default. Validation should account for that cadence rather than expecting every value to move instantly. Supported critical alarm events are routed as soon as TankActive receives them from the ATG, but alarm availability and meaning still originate with the connected system and supported configuration.
A reading that appears technically valid may still belong to the wrong tank or product. Resolve mapping questions before broad user rollout. If the gauge or source information appears incorrect, involve the qualified owner rather than editing the display to conceal the discrepancy.
How should user access be handed off?
Invite only the people authorized for the organization and give each person the access needed for their responsibilities. Confirm that users can sign in through the intended path and see the correct organization data. Do not use one shared credential as a substitute for individual access.
Review who receives operational notifications and what each recipient should do. A contact list alone is not a response process. Identify primary and backup owners for inventory, ATG alarms, connection outages, and billing or account questions as applicable.
Show users where to find the dashboard or mobile app views included in their workflow and how to contact TankActive support. Avoid promising that every ATG function appears remotely; demonstrate the supported information actually available for that connected deployment.
What should you verify before handoff?
- Every expected tank appears under the correct location and product.
- Current inventory, data freshness, and supported ATG status are checked against the source and operating context.
- Received supported alarm and delivery information is reviewed where it is part of the deployment.
- The right users can sign in and see only the organization data assigned to them.
- Notification destinations, operational thresholds, and response owners match the approved operating plan.
- The connection owner, operating contact, support contact, and escalation path are known.
- Open items, limitations, and follow-up owners are written down rather than left as verbal assumptions.
How does TankActive help after activation?
Watch the new connection during normal operations and investigate gaps, unexpected mappings, repeated offline periods, or missing supported records. Early follow-up should test the operating process as well as the technology: recipients need to recognize the location, understand the notification, and know who owns the next action.
Include the connection in future change management. ATG service, router replacement, firewall changes, cellular work, power changes, tank remapping, or staff turnover can affect monitoring even when the original setup was correct. Revalidate the affected scope after material changes.
TankActive support is available at support@tankactive.com or +1 (631) 981-2001, Monday–Friday, 8:00 AM–5:00 PM Eastern. Response timing depends on request volume and issue complexity. For a useful support handoff, include the organization, location, affected ATG or tank, last known good time, observed behavior, and any recent changes without including passwords.
How can I put this guide into practice?
Use these product-specific help articles for the matching TankActive workflow.